FWN04AAFN6V3 |
FWN05AAFN6V3 |
FWN06AAFN6V3 |
FWN07AAFN6V3 |
FWN08AAFN6V3 |
FWN10AAFN6V3 |
Niveau de pression sonore
|
Sound pressure level-=-Low-=-dBA
|
dBA
|
49 (5)
|
49 (5)
|
54 (5)
|
56 (5)
|
57 (5)
|
57 (5)
|
|
Sound pressure level-=-High-=-dBA
|
dBA
|
61 (5)
|
61 (5)
|
64 (5)
|
64 (5)
|
67 (5)
|
67 (5)
|
Total sound power level
|
Total sound power level-=-Low-=-dBA
|
dBA
|
54 (4)
|
54 (4)
|
59 (4)
|
61 (4)
|
62 (4)
|
62 (4)
|
|
Total sound power level-=-High-=-dBA
|
dBA
|
66 (4)
|
66 (4)
|
69 (4)
|
69 (4)
|
72 (4)
|
72 (4)
|
Water flow
|
Water flow-=-Cooling
|
Water flow-=-Cooling-=-Low-=-l/h
|
l/h
|
491 (1)
|
584 (1)
|
904 (1)
|
998 (1)
|
1,075 (1)
|
1,185 (1)
|
|
|
Water flow-=-Cooling-=-High-=-l/h
|
l/h
|
666 (1)
|
810 (1)
|
1,040 (1)
|
1,148 (1)
|
1,322 (1)
|
1,476 (1)
|
|
Water flow-=-Heating
|
Water flow-=-Heating-=-High-=-l/h
|
l/h
|
342 (3)
|
340 (3)
|
501 (3)
|
496 (3)
|
700 (3)
|
695 (3)
|
|
|
Water flow-=-Heating-=-Low-=-l/h
|
l/h
|
283 (3)
|
283 (3)
|
460 (3)
|
456 (3)
|
614 (3)
|
612 (3)
|
|
Water flow-=-Water pressure drop
|
Water flow-=-Water pressure drop-=-Heating
|
Water flow-=-Water pressure drop-=-Heating-=-High-=-kPa
|
kPa
|
7 (3)
|
7 (3)
|
14 (3)
|
12 (3)
|
10 (3)
|
25 (3)
|
|
|
|
Water flow-=-Water pressure drop-=-Heating-=-Low-=-kPa
|
kPa
|
5 (3)
|
5 (3)
|
12 (3)
|
10 (3)
|
8 (3)
|
20 (3)
|
|
|
Water flow-=-Water pressure drop-=-Cooling
|
Water flow-=-Water pressure drop-=-Cooling-=-High-=-kPa
|
kPa
|
7 (1)
|
7 (1)
|
14 (1)
|
12 (1)
|
10 (1)
|
25 (1)
|
|
|
|
Water flow-=-Water pressure drop-=-Cooling-=-Low-=-kPa
|
kPa
|
10 (1)
|
8 (1)
|
18 (1)
|
15 (1)
|
16 (1)
|
10 (1)
|
Raccords de tuyauterie
|
Évacuation
|
DE
|
mm
|
17
|
17
|
17
|
17
|
17
|
17
|
Puissance absorbée
|
Power input-=-High-=-kW
|
kW
|
0.112
|
0.112
|
0.152
|
0.152
|
0.248
|
0.248
|
|
Power input-=-Low-=-kW
|
kW
|
0.45
|
0.40
|
0.10
|
0.10
|
0.12
|
0.12
|
Allowed water temperature
|
Allowed water temperature-=-Heating
|
Allowed water temperature-=-Heating-=-Max.-=-°C
|
°C
|
95.000
|
95.000
|
95.000
|
95.000
|
95.000
|
95.000
|
|
|
Allowed water temperature-=-Heating-=-Min.-=-°C
|
°C
|
5.00
|
5.00
|
5.00
|
5.00
|
5.00
|
5.00
|
|
Allowed water temperature-=-Cooling
|
Allowed water temperature-=-Cooling-=-Min.-=-°C
|
°C
|
5
|
5
|
5
|
5
|
5
|
5
|
|
|
Allowed water temperature-=-Cooling-=-Max.-=-°C
|
°C
|
95.0
|
95.0
|
95.0
|
95.0
|
95.0
|
95.0
|
Dimensions
|
Unité
|
Largeur
|
mm
|
754
|
754
|
964
|
964
|
1,170
|
1,170
|
|
|
Profondeur
|
mm
|
280
|
280
|
280
|
280
|
280
|
280
|
|
|
Hauteur
|
mm
|
559
|
559
|
559
|
559
|
559
|
559
|
Water connections
|
Water connections-=-Additional coil-=-inch
|
pouce
|
3/4 "
|
3/4 "
|
3/4 "
|
3/4 "
|
3/4 "
|
3/4 "
|
|
Water connections-=-Primary coil-=-inch
|
pouce
|
3/4 "
|
3/4 "
|
3/4 "
|
3/4 "
|
3/4 "
|
3/4 "
|
Poids
|
Unité
|
kg
|
34.7
|
35.5
|
43.2
|
44.4
|
50.3
|
51.7
|
Ventil.
|
Débit d'air
|
Fan-=-Air flow rate-=-Low-=-m³/h
|
m³/h
|
531
|
529
|
1,005
|
985
|
1,192
|
1,184
|
|
|
Fan-=-Air flow rate-=-High-=-m³/h
|
m³/h
|
793
|
783
|
1,211
|
1,182
|
1,576
|
1,550
|
|
Fan-=-Available static pressure
|
Fan-=-Available static pressure-=-High-=-Pa
|
Pa
|
65
|
65
|
59
|
59
|
67
|
66
|
|
|
Fan-=-Available static pressure-=-Low-=-Pa
|
Pa
|
29
|
30
|
41
|
41
|
38
|
38
|
Cooling capacity (standard conditions)
|
Cooling capacity (standard conditions)-=-Total capacity 4-pipe
|
Cooling capacity (standard conditions)-=-Total capacity 4-pipe-=-Low-=-kW
|
kW
|
2.82 (1)
|
3.36 (1)
|
5.17 (1)
|
5.71 (1)
|
6.14 (1)
|
6.77 (1)
|
|
|
Cooling capacity (standard conditions)-=-Total capacity 4-pipe-=-High-=-kW
|
kW
|
3.76 (1)
|
4.61 (1)
|
5.91 (1)
|
6.55 (1)
|
7.46 (1)
|
8.35 (1)
|
|
Cooling capacity (standard conditions)-=-Sensible capacity 4-pipe
|
Cooling capacity (standard conditions)-=-Sensible capacity 4-pipe-=-Low-=-kW
|
kW
|
2.18 (1)
|
2.52 (1)
|
3.84 (1)
|
4.30 (1)
|
4.96 (1)
|
5.34 (1)
|
|
|
Cooling capacity (standard conditions)-=-Sensible capacity 4-pipe-=-High-=-kW
|
kW
|
2.95 (1)
|
3.53 (1)
|
4.39 (1)
|
4.97 (1)
|
6.19 (1)
|
6.71 (1)
|
Heating capacity (standard conditions)
|
Heating capacity (standard conditions)-=-Capacity 4-pipe
|
Heating capacity (standard conditions)-=-Capacity 4-pipe-=-Low-=-kW
|
kW
|
3.23 (3)
|
3.23 (3)
|
5.25 (3)
|
5.21 (3)
|
7.02 (3)
|
6.99 (3)
|
|
|
Heating capacity (standard conditions)-=-Capacity 4-pipe-=-High-=-kW
|
kW
|
3.91 (3)
|
3.89 (3)
|
5.72 (3)
|
5.65 (3)
|
7.99 (3)
|
7.94 (3)
|
Power supply
|
Power supply-=-Type
|
|
230 / 1 / 50
|
230 / 1 / 50
|
230 / 1 / 50
|
230 / 1 / 50
|
230 / 1 / 50
|
230 / 1 / 50
|
|
Phase
|
|
1~
|
1~
|
1~
|
1~
|
1~
|
1~
|
|
Fréquence
|
Hz
|
50
|
50
|
50
|
50
|
50
|
50
|
|
Tension
|
V
|
230
|
230
|
230
|
230
|
230
|
230
|
Remarques
|
(1) - Rafraîchissement : temp. intérieure 27 °CBS, 19 °CBH ; temp. eau en entrée 7 °C, élévation de la température de l'eau 5 K.
|
(1) - Rafraîchissement : temp. intérieure 27 °CBS, 19 °CBH ; temp. eau en entrée 7 °C, élévation de la température de l'eau 5 K.
|
(1) - Rafraîchissement : temp. intérieure 27 °CBS, 19 °CBH ; temp. eau en entrée 7 °C, élévation de la température de l'eau 5 K.
|
(1) - Rafraîchissement : temp. intérieure 27 °CBS, 19 °CBH ; temp. eau en entrée 7 °C, élévation de la température de l'eau 5 K.
|
(1) - Rafraîchissement : temp. intérieure 27 °CBS, 19 °CBH ; temp. eau en entrée 7 °C, élévation de la température de l'eau 5 K.
|
(1) - Rafraîchissement : temp. intérieure 27 °CBS, 19 °CBH ; temp. eau en entrée 7 °C, élévation de la température de l'eau 5 K.
|
|
(2) - Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 45 °C, chute de température de l'eau 5 K.
|
(2) - Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 45 °C, chute de température de l'eau 5 K.
|
(2) - Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 45 °C, chute de température de l'eau 5 K.
|
(2) - Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 45 °C, chute de température de l'eau 5 K.
|
(2) - Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 45 °C, chute de température de l'eau 5 K.
|
(2) - Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 45 °C, chute de température de l'eau 5 K.
|
|
(3) - Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 65°C, chute de température de l'eau 10K.
|
(3) - Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 65°C, chute de température de l'eau 10K.
|
(3) - Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 65°C, chute de température de l'eau 10K.
|
(3) - Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 65°C, chute de température de l'eau 10K.
|
(3) - Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 65°C, chute de température de l'eau 10K.
|
(3) - Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 65°C, chute de température de l'eau 10K.
|
|
(4) - Niveau de puissance sonore conforme à la norme ISO3741
|
(4) - Niveau de puissance sonore conforme à la norme ISO3741
|
(4) - Niveau de puissance sonore conforme à la norme ISO3741
|
(4) - Niveau de puissance sonore conforme à la norme ISO3741
|
(4) - Niveau de puissance sonore conforme à la norme ISO3741
|
(4) - Niveau de puissance sonore conforme à la norme ISO3741
|
|
(5) - Le niveau de pression sonore est mesuré à l'aide d'un microphone placé à 1 m de l'unité.
|
(5) - Le niveau de pression sonore est mesuré à l'aide d'un microphone placé à 1 m de l'unité.
|
(5) - Le niveau de pression sonore est mesuré à l'aide d'un microphone placé à 1 m de l'unité.
|
(5) - Le niveau de pression sonore est mesuré à l'aide d'un microphone placé à 1 m de l'unité.
|
(5) - Le niveau de pression sonore est mesuré à l'aide d'un microphone placé à 1 m de l'unité.
|
(5) - Le niveau de pression sonore est mesuré à l'aide d'un microphone placé à 1 m de l'unité.
|