| EHSH04P30EF / ERGA04EAV3A | EHSH04P30EG / ERGA04EAV3A | EHSH08P30EF / ERGA06EAV3A | EHSH08P50EF / ERGA06EAV3A | EHSH08P30EG / ERGA06EAV3A | EHSH08P50EG / ERGA06EAV3A | EHSH08P30EF / ERGA08EAV3A | EHSH08P50EF / ERGA08EAV3A | EHSH08P30EG / ERGA08EAV3A | EHSH08P50EG / ERGA08EAV3A | |||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Innengerät | EHSH04P30EF | EHSH04P30EG | EHSH08P30EF | EHSH08P50EF | EHSH08P30EG | EHSH08P50EG | EHSH08P30EF | EHSH08P50EF | EHSH08P30EG | EHSH08P50EG | ||||
| Heizleistung | Nom. | kW | 4.30 (1), 4.60 (2) | 4.30 (1), 4.60 (2) | 6.00 (1), 5.90 (2) | 6.00 (1), 5.90 (2) | 6.00 (1), 5.90 (2) | 6.00 (1), 5.90 (2) | 7.50 (1), 7.80 (2) | 7.50 (1), 7.80 (2) | 7.50 (1), 7.80 (2) | 7.50 (1), 7.80 (2) | ||
| Leistungsaufnahme | Heizen | Nom. | kW | 0.840 (1), 1.26 (2) | 0.840 (1), 1.26 (2) | 1.24 (1), 1.69 (2) | 1.24 (1), 1.69 (2) | 1.24 (1), 1.69 (2) | 1.24 (1), 1.69 (2) | 1.63 (1), 2.23 (2) | 1.63 (1), 2.23 (2) | 1.63 (1), 2.23 (2) | 1.63 (1), 2.23 (2) | |
| COP | 5.10 (1), 3.65 (2) | 5.10 (1), 3.65 (2) | 4.85 (1), 3.50 (2) | 4.85 (1), 3.50 (2) | 4.85 (1), 3.50 (2) | 4.85 (1), 3.50 (2) | 4.60 (1), 3.50 (2) | 4.60 (1), 3.50 (2) | 4.60 (1), 3.50 (2) | 4.60 (1), 3.50 (2) | ||||
| Trinkwassererwärmung | Allgemein | Deklariertes Lastprofil | L | L | L | XL | L | XL | L | XL | L | XL | ||
| Durchschnittliches Klima | Energieeffizienzklasse Wasserheizung | A+ | A+ | A+ | A+ | A+ | A+ | A+ | A+ | A+ | A+ | |||
| Raumheizen | Raumheizen-=-Wasserauslass 55 °C für durchschnittliches Klima | Raumheizen-=-Wasserauslass 55 °C für durchschnittliches Klima-=-Allgemein | Raumheizen-=-Wasserauslass 55 °C für durchschnittliches Klima-=-Allgemein-=-SCOP | 3.26 | 3.25 | 3.25 | 3.27 | 3.27 | ||||||
| Raumheizen-=-Wasserauslass 55 °C für durchschnittliches Klima-=-Allgemein-=-Saisonale Effizienzklasse Raumheizen | A++ | A++ | A++ | A++ | A++ | |||||||||
| Wasserauslass 35°C für durchschnittliches Klima | Allgemein | SCOP | 4.48 | 4.48 | 4.47 | 4.47 | 4.47 | 4.47 | 4.56 | 4.56 | 4.56 | 4.56 | ||
| Saisonale Effizienzklasse Raumheizen | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | ||||
| Hinweise | (1) - Bedingung 1: Kühlen: Ta 35°C - LWE 18°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Bedingung 1: Kühlen: Ta 35°C - LWE 18°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Bedingung 1: Kühlen: Ta 35°C - LWE 18°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Bedingung 1: Kühlen: Ta 35°C - LWE 18°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Bedingung 1: Kühlen: Ta 35°C - LWE 18°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Bedingung 1: Kühlen: Ta 35°C - LWE 18°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Bedingung 1: Kühlen: Ta 35°C - LWE 18°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Bedingung 1: Kühlen: Ta 35°C - LWE 18°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Bedingung 1: Kühlen: Ta 35°C - LWE 18°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Bedingung 1: Kühlen: Ta 35°C - LWE 18°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 35°C (DT = 5°C) | ||||
| (2) - Bedingung 2: Kühlen: Ta 35°C - LWE 7°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 45°C (DT = 5°C) | (2) - Bedingung 2: Kühlen: Ta 35°C - LWE 7°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 45°C (DT = 5°C) | (2) - Bedingung 2: Kühlen: Ta 35°C - LWE 7°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 45°C (DT = 5°C) | (2) - Bedingung 2: Kühlen: Ta 35°C - LWE 7°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 45°C (DT = 5°C) | (2) - Bedingung 2: Kühlen: Ta 35°C - LWE 7°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 45°C (DT = 5°C) | (2) - Bedingung 2: Kühlen: Ta 35°C - LWE 7°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 45°C (DT = 5°C) | (2) - Bedingung 2: Kühlen: Ta 35°C - LWE 7°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 45°C (DT = 5°C) | (2) - Bedingung 2: Kühlen: Ta 35°C - LWE 7°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 45°C (DT = 5°C) | (2) - Bedingung 2: Kühlen: Ta 35°C - LWE 7°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 45°C (DT = 5°C) | (2) - Bedingung 2: Kühlen: Ta 35°C - LWE 7°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 45°C (DT = 5°C) | |||||
| Raumheizen | Raumheizen-=-Wasserauslass 55 °C für durchschnittliches Klima | Raumheizen-=-Wasserauslass 55 °C für durchschnittliches Klima-=-Allgemein | Raumheizen-=-Wasserauslass 55 °C für durchschnittliches Klima-=-Allgemein-=-SCOP | 3.26 | 3.25 | 3.25 | 3.27 | 3.27 | ||||||
| Raumheizen-=-Wasserauslass 55 °C für durchschnittliches Klima-=-Allgemein-=-Saisonale Effizienzklasse Raumheizen | A++ | A++ | A++ | A++ | A++ | |||||||||